Fault-finding 🇦🇺 WA / AustraliaWhy does my safety switch (RCD) keep tripping for no reason?
Here are the usual causes, most likely first, and how an electrician would track it down.
Likely causes
- One faulty appliance with earth leakage
- Too many circuits/appliances on one safety switch (RCD) (combined leakage)
- Moisture in an outdoor power point (GPO) or light
- Borrowed neutral between circuits
- Faulty safety switch (RCD)
How you'd find it
- Unplug everything and reset; plug back in one at a time
- Isolate, then IR test each circuit (≥ 1 MΩ at 500 V)
- N–E test per circuit; RCD tester for trip time and current
Usual fix
Repair/replace the faulty appliance or wiring; separate borrowed neutrals; spread circuits over more safety switch (RCD)s/RCBOs.
⚠️ Safety: Stop and safely isolate before touching anything. If you're not qualified, leave it to a licensed electrician (WA licence).
Regulation: AS/NZS 3000:2018 Cl 2.6; testing Cl 8.3.6.
Study aid in plain English, not the text of the standard. Always check the current AS/NZS 3000:2018 + WA rules and your local rules. Electrical work must be done by a licensed or registered electrician.